Guide
Certificates, flash data and what the warranty covers
Every module ships with its measured watts and an EL image. That is the difference between a datasheet and a delivered product.
A module is a 25-year product with a 12-year workmanship promise, and the difference between a good and a bad factory shows up in three places: the flash-test data, the lamination process, and the bill of materials for the encapsulant and junction box.
Certificates
| Standard | Scope | Status |
|---|---|---|
| IEC 61215 | Design qualification | Certified |
| IEC 61730 | Module safety | Certified |
| IEC 62804 | PID resistance | Tested, PID-free |
| IEC 61701 | Salt mist corrosion | Certified |
| IEC 62716 | Ammonia resistance | Tested |
| ISO 9001 / 14001 | Factory management | Certified |
| UL 61730 | North America | Available on request |
What we test, and how often
- Flash test, 100 % of modules — I-V curve at STC, binned to 5 W and shipped with the data.
- EL imaging, 100 % of modules — electroluminescence catches micro-cracks that flash tests miss.
- Hi-pot — 2× Voc + 1000 V insulation test on every module.
- Lamination peel test — one module per shift, measured against the 40 N/cm specification.
- Thermal cycling and damp heat — IEC 61215 sequence on the design, quarterly on production samples.
- Mechanical load — 5400 Pa snow and 2400 Pa wind on sampled units, plus a 1.2 m drop test on packaging.
Warranty terms
| Warranty | Term | End output |
|---|---|---|
| Product (materials) | 12 years | — |
| PERC linear power | 25 years | 84.8 % |
| TOPCon linear power | 30 years | 87.4 % |
| HJT linear power | 30 years | 88.0 % |
| Flexible | 5 years | 80.0 % |
| Portable | 2 years | 80.0 % |
Where claims come from, honestly
Junction-box failures on early production, backsheet cracking in hot-humid climates, and micro-cracks from handling during installation. The first two are our problem and covered; the third is a handling issue that the EL image at packing time usually proves either way.